ARTICLE NUMBER |
---|
60201303, 60201003, 60201313 | WPC 48 V / 4000 VA (10500 VA max) 50 A - 230 V / 50-60 Hz |
TECHNICAL SPECIFICATIONS |
---|
Nominal battery voltage | 48 VDC |
Continuous power @ 25°C | 3500 VA |
Power 30 min. @ 25°C | 4000 VA |
Power 5 sec. @ 25°C | 10500 VA |
Maximum load | Up to short-circuit (fully protected) |
Maximum a-symmetric load | Up to continuous power |
Load detection (stand-by) | 2 to 25 W (AES) Automatic Enable System |
Power factor | 0.1 - 1 |
Efficiency (@ full load) | 96 % |
Consumption OFF / Stand-by / ON | 1.8 W / 2.1 W / 14 W |
Output voltage | Pure sine wave 230 VAC (+/- 2%) |
Output frequency | 50 Hz / 60 Hz (1) +/- 0.05% (crystal controlled) |
Harmonic distortion (voltage) | <2% THD |
Overload and short-circuit protection | Automatic disconnection with 3 time restart attempt |
Overheat protection | Warning before shut-off with automatic restart |
MAIN SPECIFICATIONS |
---|
Weight | 28 kg |
Dimension H x W x D [mm] | 510 x 330 x 150 mm |
Protection degree | IP21 |
Color | RAL 9003 |
Conformity | Directive EMC 2004/108/EC : EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2, 62040-2. Low voltage directive 2006/95/EC : EN 62040-1-1, EN 50091-2, EN 60950-1 |
Operating temperature range | -20..+40°C, derating to 55°C |
Relative humidity (operational) | 95% without condensation |
Ventilation | Forced from 45°C |
Warranty | 2 years |
Acoustic level | <40 dB / <45 dB (without / with ventilation) |